IP enclosure ratings. Basic orientation only; use IEC 60529 and the actual test evidence for requirements and claims. Human guide: https://ancreationoffice.com/ip-ratings.html First digit: solids/dust 0 | No rated solid-object protection. 1 | Objects 50 mm and larger. 2 | Objects 12.5 mm and larger. 3 | Objects 2.5 mm and larger. 4 | Objects 1 mm and larger. 5 | Dust-protected: limited entry permitted without harmful interference. 6 | Dust-tight: no dust entry in the test. Second digit: water 0 | No rated water protection. 1 | Vertical drips. 2 | Drips with enclosure tilted up to 15°. 3 | Spray up to 60° from vertical. 4 | Splashes from any direction. 5 | Water jets. 6 | Powerful water jets. 7 | Temporary immersion under specified test conditions. 8 | Continuous immersion under specified conditions; check depth and duration. 9 | High-pressure, high-temperature water jets. Examples IP56 | 5: dust-protected | 6: powerful water jets IP57 | 5: dust-protected | 7: temporary immersion IP67 | 6: dust-tight | 7: temporary immersion Read the digits separately: first solids/dust, then water. The first digit also addresses access to hazardous parts; this is a simplified ingress table. X means no protection level is specified for that digit; it is not the same as 0. IPX7 is commonly summarized as a 1 m, 30-minute immersion test. Exact depth/reference points depend on enclosure size and the standard; verify the actual test report. It is not an unlimited underwater-use rating. IPX7/IPX8 immersion does not automatically establish IPX5/IPX6 jet protection. Where both are needed, verify both ratings, such as IP66/IP67. Use the rating of the final installed assembly: seals, cable entries, connectors, doors and mounting matter. An enclosure rating alone does not prove the finished product has it. IP does not establish corrosion, UV, impact, explosion or overall electrical-safety performance. NEMA Types and IP codes are not interchangeable. Record the intended exposure, applicable standard/edition, exact tested assembly revision, seals/entries/connectors, test conditions and evidence. Do not claim an enclosure rating certifies the whole product. Sources: IEC 60529 catalog: https://webstore.iec.ch/en/publication/2452 UL comparison of IP digits (PDF): https://latam.ul.com/sites/default/files/2020-09/English%20-%20UL%20Hazardous%20location%20services.pdf Getac IP guide: https://www.getac.com/us/certifications/ip-rating/ ABB on jets, immersion and installed systems: https://new.abb.com/low-voltage/products/conduit-fittings/adaptaflex/news/applying-ip-ratings-to-flexible-conduit BEGIN TEST PLANNING Start the test plan while requirements are forming, before committing to a build. Use https://ancreationoffice.com/test-planning.html for the layout, prototype selection and electrical/RF, drop and submersion guidance. Download the plan, matrix and report templates there. END TEST PLANNING