Read it as two separate numbers: 6 for dust and 7 for water. IP describes enclosure protection (ingress protection) under specified tests.
The examples side by side
| Code | Solids / dust | Water |
|---|---|---|
| IP56 | 5: dust-protected | 6: powerful water jets |
| IP57 | 5: dust-protected | 7: temporary immersion |
| IP67 | 6: dust-tight | 7: temporary immersion |
IP57 and IP67 have the same water category; their dust protection differs. IP56 describes powerful jets, while IP57 describes temporary immersion.
First digit · Second digit · What to check
First digit: solid objects and dust
Basic solid-object protection
| Digit | Plain-language meaning |
|---|---|
| 0 | No rated solid-object protection. |
| 1 | Objects 50 mm and larger. |
| 2 | Objects 12.5 mm and larger. |
| 3 | Objects 2.5 mm and larger. |
| 4 | Objects 1 mm and larger. |
| 5 | Dust-protected: limited entry permitted without harmful interference. |
| 6 | Dust-tight: no dust entry in the test. |
Second digit: water
Basic water protection
| Digit | Plain-language meaning |
|---|---|
| 0 | No rated water protection. |
| 1 | Vertical drips. |
| 2 | Drips with enclosure tilted up to 15°. |
| 3 | Spray up to 60° from vertical. |
| 4 | Splashes from any direction. |
| 5 | Water jets. |
| 6 | Powerful water jets. |
| 7 | Temporary immersion under specified test conditions. |
| 8 | Continuous immersion under specified conditions; check depth and duration. |
| 9 | High-pressure, high-temperature water jets. |
X means that digit’s protection level is not specified. For example, IPX7 gives a water category without a solid-object rating. X does not mean zero.
These are short orientation tables, not the full test procedures. The first digit also addresses access to hazardous parts. Sources: IEC 60529 catalog · UL comparison of IP digits (PDF) · Getac IP guide.
Match the rating to the actual job
- IPX7 is commonly summarized as a 1 m, 30-minute immersion test. Exact depth/reference points depend on enclosure size and the standard; verify the actual test report. It is not an unlimited underwater-use rating.
- IPX7/IPX8 immersion does not automatically establish IPX5/IPX6 jet protection. Where both are needed, verify both ratings, such as IP66/IP67.
- Use the rating of the final installed assembly: seals, cable entries, connectors, doors and mounting matter. An enclosure rating alone does not prove the finished product has it.
- IP does not establish corrosion, UV, impact, explosion or overall electrical-safety performance. NEMA Types and IP codes are not interchangeable.
ABB on jets, immersion and installed systems. For a product requirement, the engineering role records the intended environment, required standard/edition, exact assembly revision and supporting test evidence. The prototype role tests that defined configuration; your Project Manager Bot buys parts that preserve it.
Read the IP guide for bots · Electrical standards sources · Back to Resources
Prepare the test plan before the build: sample choice, electrical/RF, drop and immersion guidance, with editable templates.
Everything here is a starting point. Work with artificial intelligence always needs tuning, so test it and dial it in for your own work, data and model before you rely on it.